Volumetric Footprint

This test relates to engineering requirement ER-9 which defines a volume that the station is to be contained in. The dimensions of this are 6ft length, 6ft width, and 7ft height. This was determined partly by the dimensions of a standard door way. This proves that engineering requirement 9 has not been met.

THIS TEST IS A FAIL!

Due to the redesign of the TX and RX modules we needed to implement expansion decks and thus the length of the station is 10ft.
The width of the station is 2 1/2in larger than the specification determined by the engineering requirement. This is due to incorrect data when creating the engineering requirement because the center module was already built prior to installing the remaining modules to it.

The height of the station is 2 inches smaller than the specification.